Must-Read for Electroplating Plant Owners! 3-Minute Self-Check Guide to Combat Burner "Corrosion Killers" - Save Thousands in Annual Maintenance Costs_Foshan Shunde Zhibo Burner Manufacturing Co., Ltd.
      1. 好色先生污污版,好色TV下载APP,好色TV污下载,好色先生软件APP

        Home > Company News

        Must-Read for Electroplating Plant Owners! 3-Minute Self-Check Guide to Combat Burner "Corrosion Killers" - Save Thousands in Annual Maintenance Costs

        Time:2025-04-24 Click:

        Longevity Secrets for Your Electroplating Burner: 3 High-Risk Component Inspection Methods:

        一、External Inspection (Completed in 3 Minutes)

        1️⃣ Burner Housing Surface  
        ✔️ Check: Peeling coating/rust/discoloration  
        ⚠️ Standard: No rust, intact coating  
        🔧 Tools: Visual inspection + flashlight  

        2️⃣ Pipe Connections
        ✔️ Check: Leaks/rust at flanges/threads  
        ⚠️ Standard: Tight seals, no corrosion  
        🔧 Tools: Wipe with tissue paper  

        3️⃣ Exhaust Outlet
        ✔️ Check: Carbon buildup/acidic condensate on inner walls  
        ⚠️ Standard: No sticky corrosive residue  
        🔧 Tools: Endoscope (optional)




        二、Core Internal Inspection (Requires Shutdown)

        🔥 Combustion Chamber Refractory Layer
        ✔️ Check: Cracks/spalling in refractory material 
        ❗ Risk:Acidic gases accelerate erosion!
         🔧 Method: Tap to listen for hollow sounds (indicates damage) 

        🌀 Heat Exchanger Fins
        ✔️ Check: Acid mist condensate/corrosion holes  
        🔧 Method: Clean with soft brush + compressed air

        ⚡ Electrodes & Igniter Plates
        ✔️ Check: Ceramic insulator cracks/metal oxidation  
        🔧 Tools: Multimeter to test insulation resistance 




        三、Electroplating Workshop-Specific Checks  

        ⚠️ Acid/Alkali Gas Protection 
        ✔️ Action: Test ambient air around equipment with pH test paper  
        🔌 Grounding Resistance Test 
        ✔️ Standard: Grounding resistance ≤4Ω  




        四、Emergency Response

        ⛔Immediately Shut Down the Machine if the Following Issues are Detected: 
        → Perforated heat exchanger fins  
        → Large-area spalling in combustion chamber refractory layer  
        → Electrode/ion rod insulation resistance <10MΩ  


        ⏰ Pro Tip:Perform these checks monthly to extend burner lifespan by 2-3 years and slash maintenance costs! 